Comparing a field density measurement against the lab-established maximum to check compaction adequacy.
Compacting fill soil isn't just about running a roller over it until it feels firm — it's checked numerically against a lab reference. A Proctor test compacts a soil sample at a range of moisture contents and finds the "maximum dry density" — the densest the soil can practically get, at its optimum moisture content, under a standardized compactive effort in the lab.
In the field, a density test (historically a sand-cone test, more often a nuclear density gauge today) measures the actual dry density achieved after compaction equipment has worked over the fill. Dividing the field result by the lab maximum gives relative compaction, expressed as a percentage — the number a project specification actually calls out (commonly 90–95%, with structural fill under a foundation often specified even higher).
Relative compaction (%) = (Field dry density ÷ Lab maximum dry density) × 100